==Jimenez Group Field Instruments Setup== | ==Jimenez Group Field Instruments Setup== | ||
+ | |||
+ | ====TSI 3010 CPC==== | ||
+ | (When NOT operated as part of an SMPS system) | ||
+ | * [http://www.tsi.com/uploadedFiles/3010_Service.pdf What you get] for your 2600USD during service. | ||
+ | * [http://cires.colorado.edu/jimenez-group/Field_Software/TSI3010manual.pdf Manual] | ||
+ | * Power: 120 or 240 VAC 50/60Hz, interchangeable using pull-out fuse block on rear. Standard [http://en.wikipedia.org/wiki/IEC_connector#C13_and_C14_connectors IEC cable]. | ||
+ | * Communications: 9600/7/E/1, 9-pin Dsub. | ||
+ | * Software: Use JG LabVIEW logger. | ||
+ | |||
+ | ====TSI 3786 CPC==== | ||
+ | (When NOT operated as part of an SMPS system) | ||
+ | * [http://cires.colorado.edu/jimenez-group/Field_Software/TSI3786manual.pdf Manual] | ||
+ | * Power: 100-230VAC 50/60Hz. Standard [http://en.wikipedia.org/wiki/IEC_connector#C13_and_C14_connectors IEC cable]. | ||
+ | * Communications: 115,200/8/N/1, 9-pin Dsub. | ||
+ | * Software: use JG LabVIEW logger. | ||
====TSI 4100 Flowmeters==== | ====TSI 4100 Flowmeters==== |
Revision as of 08:09, 23 April 2010
Contents
Jimenez Group Field Instruments Setup
TSI 3010 CPC
(When NOT operated as part of an SMPS system)
- What you get for your 2600USD during service.
- Manual
- Power: 120 or 240 VAC 50/60Hz, interchangeable using pull-out fuse block on rear. Standard IEC cable.
- Communications: 9600/7/E/1, 9-pin Dsub.
- Software: Use JG LabVIEW logger.
TSI 3786 CPC
(When NOT operated as part of an SMPS system)
- Manual
- Power: 100-230VAC 50/60Hz. Standard IEC cable.
- Communications: 115,200/8/N/1, 9-pin Dsub.
- Software: use JG LabVIEW logger.
TSI 4100 Flowmeters
- FILTER UPSTREAM!
- Manual
- Serial comms manual
- Power: 7.5 +/- 1.5 VDC. Can also be supplied through comms cable, see TSI manual.
- Communications: 38400/8/N/1, mini-DIN connector to 9-pin D-sub.
- Software: Use JG LabVIEW logger.
Grimm 1.109 Optical Particle Counter
- Grimm likes to call it a "spectrometer".
- dp channels are 0.25 / 0.28 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5 / 0.58 / 0.65 / 0.7 / 0.8 / 1 / 1.3 / 1.6 / 2.0 / 2.5 / 3.0 / 3.5 / 4 / 5 / 6.5 / 7.5 / 8.5 / 10 / 12.5 / 15 / 17.5 / 20 / 25 / 30 / 32 µm.
- Home page
- Intercomparison reference example
- Power: 18 VDC.
- Communications: 9600/8/N/1, 9-pin Dsub via NULL MODEM CABLE.
- Software: Use JG LabVIEW logger.
TSI 8520 DustTrak
- Manual
- Serial comms manual
- Power: 6 VDC, 300 mA.
- Communications: 1200/8/N/1, ethernet-style RJ-45 plug to 9-pin Dsub serial cable (TSI p/n 800563).
- Software: Use JG LabVIEW logger.
Jimenez Group Downloadable Field Instrument Software
This software can also be accessed via ftp client it is stored on the jimenez group server space under 'field_software'
- CPC Software
- PCI Software
- Valve Software v. 9 and 10 (discontinued)
- Master Valve Switching v1
- TSI Flowmeter Software
- Voodoo Software
- DustTrak Software
- Gimm OPC Software
- LabJack Software
Programs that use NI USB DAC devices may need the mx task updating to match the device connected to the logging PC. See instructions at http://digital.ni.com/public.nsf/allkb/9117075591E54E868625745D0053DCCA
You may also need to port the tasks over to a new logging computer, which is explained at http://digital.ni.com/public.nsf/allkb/42A2D212796B3DC2862571FF0061B402
Jimenez Group Logging Computer Setup Protocol
This list of settings&software was edited by MJC on 23rd April 2010 (St. George's Day!).
- Software to install
- LV 8.5.1
- Igor 6.1x
- Office
- Adobe Reader
- AIM(SMPS version)
- Vaisala M170 link
- Skype
- SSH
- WinSCP
- CU VPN
- Dimension4
- Chrome
- Drivers:
- LabJack control panel at http://labjack.com/support/ud/ud-setup
- LabJack LV drivers at http://labjack.com/support/ud/examples/labview
- CP210x
- Things to get rid of
- Language bar
- Desktop picture
- Junk in start menu list
- disable balloon tips
- Settings to change
- Windows update: Notify but don't download
- Power: everything "always on"
- Power: NO action on closing lid
- Regional Settings: Short date format to YYYY/MM/DD, time to 24hr HH:MM
- Logging software to load onto HDD
- LabVIEW:
- CPC
- DustTrak v4
- Flowmeter v2
- Grimm v3
- Valve switching software v1
- LabJack digital I/O
- Ozone Monitor Logging
- Jayne Valve switching software v1
- LabVIEW: