Difference between revisions of "DAURE"

From Jimenez Group Wiki
Jump to: navigation, search
Line 1: Line 1:
This Wiki is a repository of information about a field campaign to be conducted at an urban/rural site pair in Barcelona and Montseny (Catalonia, Spain) in late 2008 and 2009.  
+
This Wiki is a repository of information about a field campaign to be conducted at an urban/rural site pair in Barcelona and Montseny (Catalonia, Spain) in winter and summer 2009.  
  
 
== Objectives ==
 
== Objectives ==
  
The objectives of this campaign is to characterize the sources of fine aerosols in the Barcelona region, with particular attention to carbonaceous aerosols. The campaigns should be carried out simultaneously at two sites, one inside Barcelona (CSIC) and the [http://www.diba.cat/parcsn/parcs/mapagp.asp?par=3 rural mountain site of Montseny] (~25 km away), ideally with the same measurements at both sites.
+
The objectives of this campaign is to characterize the sources of fine aerosols in the Barcelona region, with particular attention to carbonaceous aerosols. The campaigns should be carried out simultaneously at two sites, one inside Barcelona (CSIC) and the [http://www.diba.cat/parcsn/parcs/mapagp.asp?par=3 rural mountain site of Montseny] (~50 km away), ideally with the same measurements at both sites.
  
  
== Participant Groups ==
+
== Participant Groups and Measurements ==
  
 
The following groups are likely to participate in this campaign, although in some cases this depends on funding.
 
The following groups are likely to participate in this campaign, although in some cases this depends on funding.
Line 21: Line 21:
 
* [http://lac.web.psi.ch/ Laboratory for ATmospheric Chemistry at the Paul Scherrer Institut], Switzerland
 
* [http://lac.web.psi.ch/ Laboratory for ATmospheric Chemistry at the Paul Scherrer Institut], Switzerland
 
** Measurements: Filter-based 14C (of EC, OC, WSOC, WIOC) at both sites, and one High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS)
 
** Measurements: Filter-based 14C (of EC, OC, WSOC, WIOC) at both sites, and one High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS)
 +
** Drum impactor for semi-real time measurements of inorganics
 
** Molecular tracers and NMR spectral fingerprints (through collaborators in EUCARII)
 
** Molecular tracers and NMR spectral fingerprints (through collaborators in EUCARII)
  
* Several other groups have expressed an interest in participating, including:
+
Several other groups have expressed an interest in participating, including:
  
 
** [http://www.uibk.ac.at/ionen-angewandte-physik/umwelt/members/group_members/armin_hansel.html Prof. Armin Hansel from University of Innsbruck], Austria, with the High-Resolution Proton-Transfer-Reaction Mass Spectrometer (HR-PTR-MS) for VOC detection
 
** [http://www.uibk.ac.at/ionen-angewandte-physik/umwelt/members/group_members/armin_hansel.html Prof. Armin Hansel from University of Innsbruck], Austria, with the High-Resolution Proton-Transfer-Reaction Mass Spectrometer (HR-PTR-MS) for VOC detection
 
** Prof. Phil Hopke from Clarkson Univ., US, with continuous EC/OC analyzers
 
** Prof. Phil Hopke from Clarkson Univ., US, with continuous EC/OC analyzers
  
== Tentative Dates ==
+
== Dates ==
  
 
Depending on funding and availability of personnel, we will conduct 1 or 2 campaigns. Ideally we would contrast summer and winter.  
 
Depending on funding and availability of personnel, we will conduct 1 or 2 campaigns. Ideally we would contrast summer and winter.  
Line 35: Line 36:
 
* 23-Feb-09 to 27-March-09, together with EMEP-2 campaign. PSI is available for sure and can bring HR-ToF-AMS. Also molecular tracers and spectral fingerprints.  
 
* 23-Feb-09 to 27-March-09, together with EMEP-2 campaign. PSI is available for sure and can bring HR-ToF-AMS. Also molecular tracers and spectral fingerprints.  
  
=== Other tentative dates ===
+
=== Summer 2009 tentative dates ===
* Alternative 1: Summer 2009
 
 
** Tentatively the last 3 weeks of Jul-09 and first week of Aug-09, to catch a summer period. (Eiko has a campaign 8-June to 8-July 2009 in the Netherlands, which prevents moving this time period earlier in time, if his instrument is used).
 
** Tentatively the last 3 weeks of Jul-09 and first week of Aug-09, to catch a summer period. (Eiko has a campaign 8-June to 8-July 2009 in the Netherlands, which prevents moving this time period earlier in time, if his instrument is used).
** Andre Prevot, 14-Dec-2008: We prefer a real summer campaign in 2009 over the autumn campaign during EMEP. The summer campaign could be anytime from May to August in our opinion.  
+
** Andre Prevot (Email on 14-Dec-2008): We prefer a real summer campaign in 2009 over the autumn campaign during EMEP. The summer campaign could be anytime from May to August in our opinion.  
 
We have to wait to fix the dates until we know the dates for the campaign in
 
We have to wait to fix the dates until we know the dates for the campaign in
 
Paris which is part of the Megacity EU project MEGAPOLI. We can come to  
 
Paris which is part of the Megacity EU project MEGAPOLI. We can come to  
Line 46: Line 46:
 
it at a fixed site. (Molecular tracers and spectral fingerprints will not be available)
 
it at a fixed site. (Molecular tracers and spectral fingerprints will not be available)
  
 +
=== Dates that don't work ===
 +
* We had discussed May-08, simultaneously with the EUCARII-1 campaign in Europe. However Jose cannot make this time period due to a conflict in April-08 with the NASA ARCTAS campaign.
 +
* Alternative: Mid-Sep-08 to Mid-Oct-08, together with EMEP-1 campaign. However this may be too late, as September is not as warm in Barcelona as the June-Aug period.
  
* Alternative 2: Mid-Sep-08 to Mid-Oct-08, together with EMEP-1 campaign
+
== Issues to deal with ==
  
 +
* At Mntseny the unpaved mountain road is in bad condition, and if the power demand is very high we have to change the power supply with the company, which would take time.
  
=== Dates that don't work ===
+
* Power demand of HR-ToF-AMS is ~ 1 kW (including sampling pumps).
* We had discussed May-08, simultaneously with the EUCARII-1 campaign in Europe. However Jose cannot make this time period due to a conflict in April-08 with the NASA ARCTAS campaign.
+
 
 +
* Eiko Nemitz, email of 26-Nov-2007: "
 +
I would be interested to investigate the possibility to measure NH3 and HNO3 also. Modelling of NH4NO3 is still a major uncertainty in the European regional models, including the EMEP model. We could potentially loan a simple rotating wet denuder which fills hourly samples into test tubes for subsequent laboratory analysis for NH4+ and anions (HNO3, HCl, SO2). However, this would require laboratory analysis of 24 x 30 samples + some blanks for each month by some local lab. Is there a chance for the Spanish ministry to support this measurement?"

Revision as of 22:48, 20 January 2008

This Wiki is a repository of information about a field campaign to be conducted at an urban/rural site pair in Barcelona and Montseny (Catalonia, Spain) in winter and summer 2009.

Objectives

The objectives of this campaign is to characterize the sources of fine aerosols in the Barcelona region, with particular attention to carbonaceous aerosols. The campaigns should be carried out simultaneously at two sites, one inside Barcelona (CSIC) and the rural mountain site of Montseny (~50 km away), ideally with the same measurements at both sites.


Participant Groups and Measurements

The following groups are likely to participate in this campaign, although in some cases this depends on funding.

  • Laboratory for ATmospheric Chemistry at the Paul Scherrer Institut, Switzerland
    • Measurements: Filter-based 14C (of EC, OC, WSOC, WIOC) at both sites, and one High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS)
    • Drum impactor for semi-real time measurements of inorganics
    • Molecular tracers and NMR spectral fingerprints (through collaborators in EUCARII)

Several other groups have expressed an interest in participating, including:

Dates

Depending on funding and availability of personnel, we will conduct 1 or 2 campaigns. Ideally we would contrast summer and winter.

Confirmed dates

  • 23-Feb-09 to 27-March-09, together with EMEP-2 campaign. PSI is available for sure and can bring HR-ToF-AMS. Also molecular tracers and spectral fingerprints.

Summer 2009 tentative dates

    • Tentatively the last 3 weeks of Jul-09 and first week of Aug-09, to catch a summer period. (Eiko has a campaign 8-June to 8-July 2009 in the Netherlands, which prevents moving this time period earlier in time, if his instrument is used).
    • Andre Prevot (Email on 14-Dec-2008): We prefer a real summer campaign in 2009 over the autumn campaign during EMEP. The summer campaign could be anytime from May to August in our opinion.

We have to wait to fix the dates until we know the dates for the campaign in Paris which is part of the Megacity EU project MEGAPOLI. We can come to Barcelona before or after the Paris campaign. In the summer campaign we can bring the ToF and eventually the Q-AMS. If we have another AMS at one of the fixed sites, we might bring the Q-AMS in our mobile van instead of putting it at a fixed site. (Molecular tracers and spectral fingerprints will not be available)

Dates that don't work

  • We had discussed May-08, simultaneously with the EUCARII-1 campaign in Europe. However Jose cannot make this time period due to a conflict in April-08 with the NASA ARCTAS campaign.
  • Alternative: Mid-Sep-08 to Mid-Oct-08, together with EMEP-1 campaign. However this may be too late, as September is not as warm in Barcelona as the June-Aug period.

Issues to deal with

  • At Mntseny the unpaved mountain road is in bad condition, and if the power demand is very high we have to change the power supply with the company, which would take time.
  • Power demand of HR-ToF-AMS is ~ 1 kW (including sampling pumps).
  • Eiko Nemitz, email of 26-Nov-2007: "

I would be interested to investigate the possibility to measure NH3 and HNO3 also. Modelling of NH4NO3 is still a major uncertainty in the European regional models, including the EMEP model. We could potentially loan a simple rotating wet denuder which fills hourly samples into test tubes for subsequent laboratory analysis for NH4+ and anions (HNO3, HCl, SO2). However, this would require laboratory analysis of 24 x 30 samples + some blanks for each month by some local lab. Is there a chance for the Spanish ministry to support this measurement?"