− | == 3.0.21 == | + | == 3.0.21 (07-Dec-2009) == |
+ | |||
+ | ===Changes=== | ||
+ | Now allows 0.1s Averaging in FMS mode | ||
+ | |||
+ | === Bug Fixes === | ||
+ | PTOF Display bug fixed, first display was not working in v3019 | ||
+ | |||
+ | Nitrate Loading value fixed, displayed value had error in v3019 | ||
+ | |||
+ | Swap button bug fixed, Calibration Group and Sampling Type values were lost when swap was used in previous versions | ||
== 3.0.19 (29-Sept-2009)== | == 3.0.19 (29-Sept-2009)== |
Revision as of 06:35, 7 December 2009
3.0.21 (07-Dec-2009)
Changes
Now allows 0.1s Averaging in FMS mode
Bug Fixes
PTOF Display bug fixed, first display was not working in v3019
Nitrate Loading value fixed, displayed value had error in v3019
Swap button bug fixed, Calibration Group and Sampling Type values were lost when swap was used in previous versions
3.0.19 (29-Sept-2009)
InfoVals
InfoVal(106) indicates seconds after midnight at start of run
InfoVal(107) indicates active menu number
If DIO5, 6, or 7 is in, save state as save
InfoVal(108, 109, 110) states of digital in 5, 6, 7 (NaN if disabled)
InfoVal(111) Relative time within fast MS cycle (NaN if not FMS mode)
InfoVal(112) Relative run number within FMS cycle (NaN if not FMS mode)
Menu Switching
New menu value allows optional wait at the start of a run
Added Menu Cycle Time Grid as alternative to run-based time grid
BitWise
Baseline and SI area now based on MS mode; no longer need chopper to run Bitwise
Single Ion peak list is now saved to menu file
Optional "Bitwise on the hour" measures baseline and SI area every hour
All three displayed nominal masses share a single peak discriminator, saved as menuVal
Suggests best baseline bit, see: http://tof-ams.blogspot.com/2009/08/what-is-proper-baseline-bit-value.html
Acquisition / Acquisition Window
Logic allows FMS with closed block = 0
Logic allows MS mode with % Open = 100
Added functionality and interface updates for MS acquisition without chopper (controlled with menu val 141)
Zoom windows on right side of acquisition window allow change of nominal mass with scroll wheel
If MSclosed does not exist, displayed resolution values are calculated from open data
Option to display MSClosed sticks
Horizontal zoom in stick display with mouse
Eliminated %MSOpen. MS Dwell time now calculated as (MSOpenT+MSClosedT)*MSLoopsPerDwell. Loops enables multiple MSClosed / MSOpen Dwells per dwell.
Vertical scaling in zoom windows
Check RealTime Configuration at load of window. See: http://tof-ams.blogspot.com/2009/08/quickview-warning-window.html
PTOF DC markers calculation adjusted based on number of TOF/chop and co-adds
Fixed display of speciated sticks for SP-AMS Dark Green for Cn and Fullerene
MS Stick display size depends on what other modes are active in acquisition cycle
Digital Lines
DIO5, 6, and 7 now configurable as in or out (common across menu)
If out, state unique to each menu
If in, value is recorded and saved as infoVal
Option to control acquisition start/stop from DIO5
Option to control menu switching with encoding on 6 and 7
Mass Calibration Window
Peak intensity displayed in units of Hz; calculation uses bit-ns per second, SI Area, and TOF pulser frequency
Total Ion Current (TIC) reported below trace of peak areas/heights
Option to save itx file with last acquired mass spectrum. Includes raw MS, raw mass axis, and unit mass resolution stick spectrum
Added Accumulation mode as option on tuning tab. MS data are continuously acquired and summed, allowing determination of resolution (etc) for low intensity peaks.
Window Messages
Allows control of acquire start/stop and menu number from external software with windows messages
Real Time Files / Serial Output
Write MSSDiff.itx to C:\ToFAMS\ToFAMSData\LogFiles\TimeTrace\MS for each run. Optional - controlled by check box in Real Time box on averagin and saving tab.
New Serial output formats
Front Panel
If DAQ PC has internet connection, check for updated version of DAQ. If update exists, button on panel links to download.
National Instruments
Auto-determination of National instrument board device numbers. If board(s) not found, features disabled accordingly.
3.0.3
NEW FEATURES since 3.0.0:
Acquisition Window
Optional automatic baseline and SI determination during acquisition. Turned on/off on AP240 tab of Menu Window. This is still considered a BETA feature. Last values are saved as InfoVals.
Calib Window Step sizes (volts) for TPS scans are saved as common menu values
Scroll wheel and arrow keys to change TPS voltages and calibration center points
Info Vals If TPS remote control is enabled, last monitored TPS voltages are saved as infoVals for each run
Data Save
Allows transient save in FMS mode. itx written to transient drive, without write to C: drive