Difference between revisions of "DAURE"

From Jimenez Group Wiki
Jump to: navigation, search
(Participant Groups)
(Instrumentation (only winter campaign))
Line 113: Line 113:
 
*CIEMAT
 
*CIEMAT
 
**SMPS
 
**SMPS
*UC
+
*UC-CEH
 
** ToF AMS
 
** ToF AMS
 
** Dust track
 
** Dust track

Revision as of 09:10, 9 January 2009

This Wiki is a repository of information about a field campaign to be conducted at an urban/rural site pair in Barcelona and Montseny (Catalonia, Spain) in winter and summer 2009.

Objectives

The objectives of this campaign is to characterize the sources of fine aerosols in the Barcelona region, with particular attention to carbonaceous aerosols. State-of-the-Art methods such as 14C and HR-ToF-AMS analysis have been applied or are starting to be applied to the source apportionment problem in Central Europe, but not yet in the Mediterranean region. There are reasons to believe that the results from Central Europe (dominance of biogenic and biomass burning in the organic aerosol) may not apply in the Mediterranean, and this campaign is a unique opportunity to evaluate this hypothesis (CSIC, UC, PSI, CEH, BSC, UPC,CIEMAT, UB, UGR, and other participant groups). Furthermore, Biogenic Volatile Organic Compounds emissions and concentrations in Barcelona and Montseny and their implications as sources of aerosols will be also investigated (CREAF).

Sites

The campaigns should be carried out simultaneously at two sites of NE Spain in the Mediterranean Basin

General.jpgBCN MSY.jpg Perf1.jpgPerf2.jpg

  • Site BCN will be inside Barcelona (CSIC. Located in the university campus in the western side of Barcelona close to Diagonal Avenue, one of the main traffic roads from the city. In this area we will install 2 monitoring cabins BCN_1 and BCN_2. The first consits of a conventional aerosol monitosing site containing CSIC instrumentation. BCN_2 is a small office trailer ready to install the arriving instruments (power to be discussed) and it is located only 5 m away from BCN_1.

Urban Background 41°23'24.01"N 02° 6'58.06"E

BCN 1.jpgBCN 2.jpg

BCN 1&2foto.jpg

The station is located 10 m from a University Residence and around 300 m of our Institute of Earth Sciences ‘Jaume Almera’, CSIC. It is very convenient to book rooms at this residence a.s.a.p (see details below).

  • Site MSY will be a rural mountain site at Montseny (~50 km away), ideally with the same measurements at both sites. In this area we seleceted 2 monitoring sites MSY_1 and MSY_2. The first consits of a conventional aerosol monitosing site containing CSIC instrumentation. MSY_2 is a traditional rural house plenty of space, with sleeping rooms, kitchen and very basic labs. CREAF has ge kindly allowed us to use this MSY 2 field laboratory. Spacial thanks to Javier Retana (director of CREAF)for facilitating all sort of actions to allow us organizing the measurements. This is ready to install the arriving instruments (up to 10 kW) and it is located only 200 m away from MSY_1.

Regional background MSY_1: CSIC aerosol monitoring station 41°46'45.63"N 02°21'28.92"E

MSY_2: Rural house with laboratory for DAURE 41°46'45.21"N 02°21'17.48"E

    • Additionally there will be space enough to work with a conventional mobile unit (from PSI or from AQ local agencies. Note that at Montseny the unpaved mountain road is in poor condition, and has posed problems in the past.

MSY 1.jpgMSY 2.jpg

MSY 1&2foto.jpg

MSY 1foto.jpg MSY 2foto.jpg

Participant Groups

The following groups are likely to participate in this campaign, although in some cases this depends on funding.

  • CSIC Host group: The aerosol research group at the Institute of Earth Sciences, CSIC in Barcelona, Spain (contact Xavier Querol)
    • Fuinding for CSIC participation, some logistic expenses and for 14C analysis were obtained from the Spanish Ministry of Innovation and Science: Proyecto DOASUR: CGL2007-62505/CLI. Acción Complementaria DAURE CGL2007-30502-E/CLI, and Consolider-Ingenio project GRACCIECSD 2007-00067.
  • Colorado Jimenez group at the University of Colorado-Boulder, USA
  • CEH Edinmburg, Atmospheric Sciences [1], Scotland, UK (contact person Eiko Nemitz)
  • PSI [2] Laboratory for Atmospheric Chemistry at the Paul Scherrer Institut, Switzerland
  • BSC Barcelona Supercomputing Centre, Spain
  • The CREAF [3], Spain (contact Josep Peñuelas). CREAF has ge kindly allowed us to use MSY 2 field laboratory. Special thanks are given to Javier Retana (director of CREAF)for facilitating all sort of actions to allow us organizing the measurements.
  • CIEMAT [4], Spain, with continuous OC, EC and nitrate analysis (contact Begoña Artiñano)
  • UB: Atmospheric Physics Group of the University of Barcelona, Spain [5]: Aerosol optical characterization from columnar radiometric measurements, Cimel sunphotometer, spectroradiometers and meteorological instruments (contact Jeroni Lorente)
  • UPC: Department of Signal Theory and Communications (TSC) (Lidar experts) [6], Spain (contact Adolfo Comerón and Michaël Sicard)
  • Possible participation:
    • Granada University, Spain with column aerosols measurements

Instrumentation (only winter campaign)

The following instrumentation is planned to be working during the winter campaign (the summer one will be discussed later as a function of the first results):

BCN_1

  • CSIC
    • Optical counter for PM10, PM2.5 and PM1.
    • 3 high volume samplers for PM10, PM2.5 and PM1: 12 to 24 h speciation of PM10, PM2,5 and PM1 including sulfate, nitrate, chloride, ammonium, OC, EC, Ca, Al, Fe, K, Mg, Mn, P, Ti, and 55 trace elements. Analysis will be performed after sampling with ICP-MS, ICP-AES, Sunset TO OC-EC, IC, seletive electrodes.
    • 1/2 filter of PM1 for selecetd samples will be used for 14C analysis of EC and OC
    • MAAP.
    • Water CPC (without SMPS, we would appreciate if someone bring one).
    • SO2, NOx, O3, CO (will be installed with 75% probability).
    • Met-data available from Faculty of Physics (300 m from the station).
    • Low volume sampler (Partisol) with denuder and QBQ for OC (with positive and negative artifact correction) and EC in PM2.5.

BCN_2

  • PSI
    • W-ToF-AMS.
    • Another W-ToF-AMS will be available to performs mobile and stationary measurements at the same time
    • 14C analyses on filters. 10 daily samples at MSY and 10 samples at BCN. For each sample 2 analysis, one for OC the other for EC. This will be repeated during both for winter and summer campaigns.
    • 1 rotating drum impactors (2 hourly resolution for subsequent synchrotron-XRF at PSI).
    • 1 aethalometer.
    • 1 SMPS/calibration unit
    • 1 APS
    • Mobile laboratory (AMS, MAAP, FMPS, CO2, NOx, CO) to measure at different sites at the begining and at the end of the campaign
  • CIEMAT
    • Real time measurements of nitrate R&P 8400N (PM2.5).
    • Real time measurements of EC, OC (R&P 5400).
    • Real time measurements of sulfate (Thermo).
  • UB
    • Cimel sunphotometer.
    • Spectroradiometers.
    • Meteorological instruments.

MSY_1

  • CSIC
    • Optical counter for PM10, PM2.5 and PM1.
    • 3 high volume samplers for PM10, PM2.5 and PM1: 12 to 24 h speciation of PM10, PM2,5 and PM1 including sulfate, nitrate, chloride, ammonium, OC, EC, Ca, Al, Fe, K, Mg, Mn, P, Ti, and 55 trace elements. Analysis will be performed after sampling with ICP-MS, ICP-AES, Sunset TO OC-EC, IC, seletive electrodes.
    • MAAP.
    • Butanol CPC (without SMPS, we would appreciate if someone bring one).
    • SO2, NOx, O3, CO (will be installed with 75% probability).
    • Met-data available.
    • Low volume sampler (Partisol) with denuder and QBQ for OC (with positive and negative artifact correction) and EC in PM2.5.
  • PSI
    • 1 rotating drum impactors (2 hourly resolution for subsequent synchrotron-XRF at PSI).

MSY_2

  • PSI
    • 1/2 filter of PM1 for selecetd samples will be used for 14C analysis of EC and OC
    • 14C analyses on filters. 10 daily samples at MSY and 10 samples at BCN. For each sample 2 analysis, one for OC the other for EC. This will be repeated during both for winter and summer campaigns.
  • CIEMAT
    • SMPS
  • UC-CEH
    • ToF AMS
    • Dust track
  • CREAF
    • BVOC emission rates. Leaf enclosure technique will be employed using LiCor 6400 Photosynthesis System to determine photosynthetic activity and BVOC emission flux at a given temperature, photosynthetic active radiation (PAR), relative humidity, and CO_2 concentration. Cuvette air samples will be drawn (pumped out) from the exhaust line into sampling tubes packed with adsorbents.
    • Analysis of air samples ­ C_5 to C_20 compounds will be determined. Air samples will be analyzed using gas chromatography / mass spectrometry at CREAF. In addition, scans of C_1 -C_20 VOCs will be conducted by sampling air with tedlar bags or canisters to be later analysed with PTR-MS (in case the PTR-MS itself can not be transported to the sites)
    • Calculations of biogenic VOC emission and modeling ­ emission fluxes will be calculated for different levels (1) leaf-and branch-scale, (2) canopy, and (3) landscape emission capacity model following standard algorithms with adjustments when appropriate.

BCN3

  • BSC-UPC
    • Meteo and AQ modeling and forecast (CMAQ, WRF) CALIOPE project [7]
    • African dust modeling and forecast BSC-DREAM [8]
  • UPC
    • Lidar measurements for PM upto 5km high each Monday and Thursday. Additionally, 2 more measurements/week around 01:00 UTC and 13:00 UTC, coinciding with CALIPSO passage over Barcelona.

ADDITIONALLY PLEASE PSI HAS TO CONFIRM:

    • Molecular tracers and NMR spectral fingerprints (through collaborators in EUCARII)

Dates

If sufficient funding and personnel are available, we will conduct 2 campaigns to contrast summer and winter at the paired urban/rural sites.

Confirmed dates in Winter/Spring 2009

  • 23-Feb-09 to 27-March-09, together with EMEP-2 campaign. PSI is available for sure and can bring HR-ToF-AMS. Also molecular tracers and spectral fingerprints.

Tentative Dates in Summer 2009

  • Tentatively the last 3 weeks of Jul-09 and first week of Aug-09, to catch a summer period. (Eiko has a campaign 8-June to 8-July 2009 in the Netherlands, which prevents moving this time period earlier in time, if his instrument is used).
  • Andre Prevot (Email on 14-Dec-2008): "We prefer a real summer campaign in 2009 over the autumn campaign during EMEP. The summer campaign could be anytime from May to August in our opinion. We have to wait to fix the dates until we know the dates for the campaign in Paris which is part of the Megacity EU project MEGAPOLI. We can come to Barcelona before or after the Paris campaign. In the summer campaign we can bring the ToF and eventually the Q-AMS. If we have another AMS at one of the fixed sites, we might bring the Q-AMS in our mobile van instead of putting it at a fixed site. (Molecular tracers and spectral fingerprints will not be available)"

Dates that don't work

  • We had discussed May-08, simultaneously with the EUCARII-1 campaign in Europe. However Jose cannot make this time period due to a conflict in April-08 with the NASA ARCTAS campaign.
  • Alternative: Mid-Sep-08 to Mid-Oct-08, together with EMEP-1 campaign. However this may be too early for several of the groups involved, and too late meteorologically, as September is not as warm in Barcelona as the June-Aug period.

Logistics

  • Accomodation

We recommend booking a.s.a.p accomodation at vthe following residence:

Residencia Torre Girona

Passeig dels Til•lers, 19

08034 Barcelona

Telephon: (0034) 93 390 43 00

Fax: (0034) 93 205 69 10

E-mail: torregirona@resa.es

Price of a single room:

1 month: 652 Euros (room only, without breakfast, you will have a small kitchen in the rrom) + 75 Euros contract for 2008. Additional fees: 12+35 Euros for water and electricity consumption IMPORTANT: WHEN BOOKING PLEASE MENTION THAT THE BOOKING IS IN THE FRAMEWORK OF 'DAURE' PRICES ARE MUCH REDUCED BECAUSE WE GET THE RATES FOR UPC UNIVERSITY STAFF, OTHERWISE IT IS MUCH MORE EXPENSIVE. 1 day: Single Monday to Friday 62.5 Euros, Week end 51.5 Euros [9]

Location: [10]

At Montseny there is free (very basic) accomodation if you bring sheets and a blanket or a sleeping bag. The rural house has central heating and a fireplace but this can not be used. We will get electric heaters. Telephone, water, power, beds, a basic lab, some offices and a kitchen will be available. We are trying to get internet there but this may be not possible. Cellular phones from Movistar get service there but Vodafone dont.

The main problem at Montseny is the access road (gravel / rock) which can be difficult, especially in case of snow.

Normal cars may have difficulties in travelling across this track.

Closest vilages to Montseny site are: Santa María de Palautordera and Sant Esteve de Palautordera. Restaurants and accomodation are available also overthere. Montseny is 1.5 h driving from Barcelona and 20 min from the above villages.

Issues to deal with

  • Eiko Nemitz, email of 26-Nov-2007: "I would be interested to investigate the possibility to measure NH3 and HNO3 also. Modelling of NH4NO3 is still a major uncertainty in the European regional models, including the EMEP model. We could potentially loan a simple rotating wet denuder which fills hourly samples into test tubes for subsequent laboratory analysis for NH4+ and anions (HNO3, HCl, SO2). However, this would require laboratory analysis of 24 x 30 samples + some blanks for each month by some local lab. Is there a chance for the Spanish ministry to support this measurement?"
  • Check water supply MSY
  • Verifying power at MSY_2
  • Rent a container for instruments and computers at BCN_2 (may be not needed if PSI brings trailer)
  • 2 mobile units fro AQ monitoring booked at local AQ agency, but may be not needed if CSIC's cabins are equipped with instruments for gaseous pollutants (in progress).
  • Booking 2 cars at CSIC for 15 Feb to 27 de March
  • May be it is necessary to rent a pick up for transporting aerodyne to MSY
  • CSIC does not has SMPS systems, solutions for this. May be we may buy DMA-Electrometrefrom TSI UFIPOLNET?????????
  • Denuders fro OC for partisol: nned to build 2 of them
  • Interesting having Radon measurements from UPC?
  • Internet MSY
  • AERODYNE Mini-AMS (50% possibilities)check if possible
  • CLARKSON UNIVERSITY: Real time sulfate????? chek if possible
  • CIEMAT: Nitrate, OC and EC real time check if possible
  • GRANADA UNIVERSITY Column aerosol measurement instrumentation (CIMEL and others) check availability