Difference between revisions of "ToF-AMS Main"
(→Procedures) |
(→FAQS) |
||
(17 intermediate revisions by 6 users not shown) | |||
Line 5: | Line 5: | ||
It is based on the highly successful design of the first generation quadrupole-based | It is based on the highly successful design of the first generation quadrupole-based | ||
system, the [http://cires.colorado.edu/jimenez-group/QAMSResources/ Q-AMS]. The ToF-AMS differs from the Q-AMS in the replacement of the quadrupole mass filter, with a custom designed [http://tofwerk.com/ Tofwerk] time-of-flight mass Spectrometer. | system, the [http://cires.colorado.edu/jimenez-group/QAMSResources/ Q-AMS]. The ToF-AMS differs from the Q-AMS in the replacement of the quadrupole mass filter, with a custom designed [http://tofwerk.com/ Tofwerk] time-of-flight mass Spectrometer. | ||
+ | |||
+ | Note that the information in this Wiki and associated web pages is provided here with the hope that it is useful, but this is a volunteer project, and we cannot guarantee that everything is correct and up-to-date. Please contact Aerodyne directly to obtain the latest information. | ||
== Hardware == | == Hardware == | ||
Line 16: | Line 18: | ||
=== FAQS === | === FAQS === | ||
* [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQ_AMS_Hardware FAQs for AMS Hardware] | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQ_AMS_Hardware FAQs for AMS Hardware] | ||
+ | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQ_for_AMS_Data_Users FAQs for AMS Data Users] | ||
=== Procedures === | === Procedures === | ||
* [http://cires.colorado.edu/jimenez-group/Reference/2005-07_ToF-AMS_v1.xls ToF-AMS Quick Start-up Checklist] (xls) | * [http://cires.colorado.edu/jimenez-group/Reference/2005-07_ToF-AMS_v1.xls ToF-AMS Quick Start-up Checklist] (xls) | ||
+ | * [http://cires.colorado.edu/jimenez-group/Reference/AMS_DailyCheckSheet.xls 2011 Ongoing Field Campaign Checklist] (xls) | ||
+ | * [http://cires.colorado.edu/jimenez-group/Reference/SEAC4RS_Checklist.docx 2013 SEAC4RS campaign final Checklist] (docx) | ||
+ | * [http://cires.colorado.edu/jimenez-group/Reference/DC3_Checklist.docx 2013 DC3 campaign final Checklist] (docx) (older than prev., keep for reference) | ||
* [http://cires.colorado.edu/jimenez-group/wiki/index.php/Field_ToF-AMS_Operation ToF-AMS Field Operation Guide] | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/Field_ToF-AMS_Operation ToF-AMS Field Operation Guide] | ||
− | * [http://cires.colorado.edu/jimenez-group/Reference/ams_vacuum_failure_plan.xls AMS Vacuum Failure Plan] (xls) | + | * [http://cires.colorado.edu/jimenez-group/Reference/ams_vacuum_failure_plan.xls AMS Vacuum Failure Plan] (xls, Advanced, check with Aerodyne before trying) |
− | * [ftp://ftp.aerodyne.com/users/Jayne/PumpControl/ToF_AMS_Vacuum_Startup.pdf Vacuum System Startup | + | * [ftp://ftp.aerodyne.com/users/Jayne/PumpControl/ToF_AMS_Vacuum_Startup.pdf Vacuum System Startup Procedure] |
− | * [http://cires.colorado.edu/jimenez-group/Reference/ | + | * [http://cires.colorado.edu/jimenez-group/Reference/2010-05-13_MJC_HeaterBoard_ParamsAdjCals.ppt Procedures to measure, calibrate and troubleshoot heater board voltages] (ppt) (with thanks to Bill Brooks) |
== Software == | == Software == | ||
=== Data Acquisition (DAQ) === | === Data Acquisition (DAQ) === | ||
− | * [ | + | * [https://sites.google.com/site/tofamsdaq/ DAQ Home] (Downloads, FAQs, Release Notes, and Feature Request) |
− | |||
− | |||
− | |||
=== Data Analysis === | === Data Analysis === | ||
Line 43: | Line 46: | ||
** [http://cires.colorado.edu/jimenez-group/wiki/index.php/HR_Ion_List HR Ion List history page] | ** [http://cires.colorado.edu/jimenez-group/wiki/index.php/HR_Ion_List HR Ion List history page] | ||
* [http://cires.colorado.edu/jimenez-group/wiki/index.php/AMS_Elemental_Analysis AMS Elemental Analysis] | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/AMS_Elemental_Analysis AMS Elemental Analysis] | ||
+ | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQs_AMS_Data_Analysis FAQs for AMS Analysis] | ||
== Data Products == | == Data Products == | ||
Line 48: | Line 52: | ||
* [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQ_for_AMS_Data_Users FAQs for AMS Data Users] | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQ_for_AMS_Data_Users FAQs for AMS Data Users] | ||
− | == | + | == Reference Information == |
+ | |||
* [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQ_AMS_Glossary Glossary of AMS related terms and acronyms] | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/FAQ_AMS_Glossary Glossary of AMS related terms and acronyms] | ||
− | |||
− | |||
* [http://cires.colorado.edu/jimenez-group/wiki/index.php/AMSUsrMtgs AMS Users Meetings] | * [http://cires.colorado.edu/jimenez-group/wiki/index.php/AMSUsrMtgs AMS Users Meetings] | ||
Line 58: | Line 61: | ||
* [http://cires.colorado.edu/jimenez/Papers/DeCarlo_HRToFAMS_complete_published.pdf DeCarlo et al., 2006] (paper that describes HR-ToF-AMS) | * [http://cires.colorado.edu/jimenez/Papers/DeCarlo_HRToFAMS_complete_published.pdf DeCarlo et al., 2006] (paper that describes HR-ToF-AMS) | ||
* [http://cires.colorado.edu/jimenez/Papers/Canagaratna_Review_Published.pdf Canagaratna et al., 2007] (review paper on all AMS types and uses) | * [http://cires.colorado.edu/jimenez/Papers/Canagaratna_Review_Published.pdf Canagaratna et al., 2007] (review paper on all AMS types and uses) | ||
− | * [http://cires.colorado.edu/jimenez/ams-papers.html Publications using all versions of the AMS] | + | * [http://cires.colorado.edu/jimenez/ams-papers.html Publications using all versions of the AMS] (see list of key papers about different topics, at the top of the page) |
− | |||
− | |||
− | |||
− |
Latest revision as of 10:06, 6 January 2017
The Time-of-Flight Aerosol Mass Spectrometer (ToF-AMS) is a second generation instrument for the real-time measurement of size-resolved aerosol chemical composition. The ToF-AMS is commercialized by Aerodyne Research, and was developed by Aerodyne in collaboration with Tofwerk AG, the Jimenez Group at the University of Colorado, the Borrmann Group at the Max Planck Institute for Chemistry, and the Coe Group at the University of Manchester.
It is based on the highly successful design of the first generation quadrupole-based system, the Q-AMS. The ToF-AMS differs from the Q-AMS in the replacement of the quadrupole mass filter, with a custom designed Tofwerk time-of-flight mass Spectrometer.
Note that the information in this Wiki and associated web pages is provided here with the hope that it is useful, but this is a volunteer project, and we cannot guarantee that everything is correct and up-to-date. Please contact Aerodyne directly to obtain the latest information.
Contents
Hardware
Manuals and Specifications
- Q-AMS Manual at Aerodyne.com
- Older Q-AMS Manual (pdf)
- Pump Control Manual
- Spec Sheets for TOF components (password protected)
FAQS
Procedures
- ToF-AMS Quick Start-up Checklist (xls)
- 2011 Ongoing Field Campaign Checklist (xls)
- 2013 SEAC4RS campaign final Checklist (docx)
- 2013 DC3 campaign final Checklist (docx) (older than prev., keep for reference)
- ToF-AMS Field Operation Guide
- AMS Vacuum Failure Plan (xls, Advanced, check with Aerodyne before trying)
- Vacuum System Startup Procedure
- Procedures to measure, calibrate and troubleshoot heater board voltages (ppt) (with thanks to Bill Brooks)
Software
Data Acquisition (DAQ)
- DAQ Home (Downloads, FAQs, Release Notes, and Feature Request)
Data Analysis
- Wiki
- Download Page (IE, SQUIRREL, PIKA)
- Squirrel and Pika Programming to do list
Data Analysis Resources
- ToF-AMS Field Data Analysis Guide
- HR-ToF Data Analysis Guide
- AMS Elemental Analysis
- FAQs for AMS Analysis
Data Products
Reference Information
- Drewnick et al., 2005 (paper that describes C-ToF-AMS)
- DeCarlo et al., 2006 (paper that describes HR-ToF-AMS)
- Canagaratna et al., 2007 (review paper on all AMS types and uses)
- Publications using all versions of the AMS (see list of key papers about different topics, at the top of the page)