Difference between revisions of "ToF-AMS DAQ"
From Jimenez Group Wiki
Joel Kimmel (talk | contribs) (→Latest Versions) |
Joel Kimmel (talk | contribs) (→Latest Versions) |
||
Line 23: | Line 23: | ||
|29-Jan-2010 | |29-Jan-2010 | ||
|BETA | |BETA | ||
− | |[[ToF-AMS_DAQ_Release_Notes# | + | |[[ToF-AMS_DAQ_Release_Notes#4.0.0 | Read]] |
[http://cires.colorado.edu/jimenez-group/ToFAMSResources/ToFSoftware/Downloads/Supplemental/v4FirstInstall.pdf '''Notes on First Install'''] | [http://cires.colorado.edu/jimenez-group/ToFAMSResources/ToFSoftware/Downloads/Supplemental/v4FirstInstall.pdf '''Notes on First Install'''] | ||
|} | |} |
Revision as of 15:57, 5 April 2011
See Also: ToF-AMS DAQ FAQs; ToF-AMS DAQ Release Notes; ToF-AMS Main
Contents
Latest Versions
Version | Date | Type | Release Notes |
---|---|---|---|
V3.1.0 | 23-August-2010 | Public | Read |
V4.0.0 | 29-Jan-2010 | BETA | Read |
News
- 23-Aug-2010 v3.1.0 posted. Stable version with heavy testing during the CalNex campaign. All changes detailed in release notes.
Known Bugs in Recent Releases
Severity | Window | Description | Work around | Fixed In Version |
---|---|---|---|---|
Minor | Acquisition (Gen-Alt, PToF) | If PToF AND BFSP active in Gen-Alt, data from first pass (e.g. 5 s) through PToF is cleared and not included in saved average. | None. | 3.1.1 |
Minor | Acquisition (Gen-Alt, Non-Autosave) | If BFSP active in Gen-Alt and Autosave off, BFSP skipped after first GenAlt cycle. | None. | 3.1.1 |
Minor | Acquisition (FMS) | If DAQ is in FMS mode at midnight, system will get stuck indefinitely acquiring FMS data in fixed chopper position. | None. | 3.1.1 |
Other Downloads
Supplemental
Name | Date | Notes | Link |
---|---|---|---|
ToF-AMS DAQ dlls | Necessary for v2.2.22+ | Download (.zip) | |
CRITR 1.1 | Program for movement of chopper, TOF Triggering, and monitor/save of slow board voltages | Download | |
DAQ QuickView Display | By D. Sueper. Save to C:\ToFAMS\ToFAMSData\LogFiles\TimeTrace | Download | |
Exact Mass File (v1.1) | 19-Mar-2007 | Displays list of m/z values in calibration window. Save to C:\ToFAMS\ToFAMSCode. | Download |
Compress HDF files | 25-May-2009 | By D.Sueper. A stand-alone ipf file that compresses existing DAQ .hdf files. | Download |
Diagnostics (v1) | 23-Aug-10 | A simple exe for diagnosing certain AMS problems. Use only if instructed to do so. Save to AMS PC, run, and email generated text to Joel. | Download |
MakeDotSet (v1) | 14-Oct-2010 | Generate a TPS .set file from a ToF-AMS Menu file (.prm). | Download |
External
Name | Notes | Link |
---|---|---|
Tofwerk TPS Control Software | Email Joel | |
NI-DAQmx | DAQ Requires v8.6.1 | link |
Acqiris Digitizer Software and Drivers | Follow Link or Search "Acqiris Software" at Agilent.com | Link |
Microsoft .NET Framework Version 1.1 | Follow Link or Search "Framework 1.1" at Microsoft.com | Link |
Documentation
ToF-AMS DAQ Manual
v4.0.X (.pdf) (Most recent beta version)
Release Notes
- ToF-AMS DAQ Release Notes Compiled release notes for v3.0.3+
- Archive of release notes for v2.1.4 and earlier.
- Notes on first install of a ToF-AMS DAQ version requiring NIDAQmx.
Technical Specifications for LS Mode (.pdf)